Reprinted June 2017, with permission, from Vol. 10 Issue 6, Pages 1,4,5
Gordon’s Clinical Observations: Endodontic treatment is a nearly daily procedure for most general dentists, and the relatively low overhead makes this treatment very profitable if accomplished correctly. The introduction of lower-cost endo files has many clinicians wondering if these files are clinically acceptable and as efficient as conventional higher-cost files. CR scientists and clinicians, assisted by a survey of practitioners, help you decide if these inexpensive files are right for you.
User ratings for EdgeFile, WaveOne Gold, ProTaper, and Endosequence
CR CONCLUSIONS:Clinical and laboratory evaluations found the EdgeFile to have clinically acceptable performance with a cost significantly lower than other leading brands.Users noted its flexibility, strength, and ability to hold its shape. They rated file separation as similar to other brands, which was confirmed with controlled tests. Low cost makes single use of endo files a more viable option. Design features and metallurgy differ among brands, and clinicians should consider all factors when choosing files, including feel, efficiency, aggressiveness, flexibility, shape, familiarity, cost, compatibility with obturation, etc.
EdgeEndo® files continue to be recognized as superior files. Many manufacturers are focused on refining the performance of NiTi. In recent studies conducted by university students and presented at the AAE conference, EdgeFile® was shown to be significantly more resistant to cyclic fatigue. Cyclic fatigue of a NiTi file occurs when the metal blade is subjected to repeated cycles of tension and compression that lead to stress and hardening of the material. In this study the six rotary files were tested for cyclic fatigue in an artificial canal. The survival of the instruments were tested using Weibull reliability test.
Introduction
Cyclic fatigue occurs due to recurrent tension and compression inside the curved canals that leads to crack formation and propagation that progresses until failure. Many factors affect instrument cyclic fatigue including the type of wire that the instrument is made of, instrument design, instrumentation motion and surface integrity.
The efforts of manufacturers are consistently focused on refining the performance of instruments and increasing their resistance to fracture. Instrument modifications include surface electropolishing, changes in the file design and cross section and the use of reciprocating motions rather than continuous motions.
Recently, Thermal treatment optimizes the microstructure and maximizes the flexibility and resistance to cyclic fatigue of an instrument.
Today, instruments make of controlled memory wires have been introduced to the market and exhibit greater resistance to cyclic fatigue that regular NiTi alloys.
Aim
To compare the cyclic fatigue of six rotary instruments with different nickel-titanium (NiTi) wires.
Method
F2 ProTaper Universal® (PT) and ProTaper Gold® (PTG) (Dentsply, Tulsa Dental Specialties, Tulsa OK, USA), C2 EdgeFile® (EF) (EdgeEndo, Albuquerque NM, USA), R25 RECIPROC® (RC) (VDW, Munich, Germany), Primary WaveOne® (WO) (Dentsply, Taillefer, Ballaigues, Switzerland), and #25 OneShape® (OS) (Micro-Mega, Besancon Cedex, France) (n-15 instruments) were tested for cyclic fatigue in an artificial canal with a 6-mm radium and a 45 degree curvature. The artificial canal within a stainless steel block was milled by using laser with the aid of computer program which reproduced the instrument size and taper and preserved the instruments trajectory that was adapted to the parameters selected. Number of cycles to fatigue (NCF) was recorded; the lateral surface and fractured face of segments were examined using scanning electron microscopy (SEM) and the cross sectional area was measured. One-way ANOVAs and Games-Howell tests were utilized for data analysis.
Results
The EdgeFile had significantly greater resistance to cyclic fatigue, followed by the RC, WO, PTG, OS and PT (p<0.05). The WO and RC were significantly more resistant to cyclic fatigue than the PTG, OS, and PT.
No significant difference was found between the OS and the PTG (p<0.05), and the PT exhibited the lowest resistance to cyclic fatigue compared to the other systems (p<0.05).
Conclusion
The EdgeFile® was significantly more resistant to cyclic fatigue and was followed by the RECIPROC, WaveOne, ProTaper Gold, OneShape and ProTaper rotary files.
The improvements to rotary instruments were proven to increase their resistances to cyclic fatigue.
EdgeEndo® FireWire™ NiTi
EdgeEndo® proprietary heat treatment process called FireWire™ has created NiTi unmatched flexibility and resistance to cyclic fatigue. FireWire™ NiTi files provide cyclic fatigue resistance many times greater than other NiTi files. The increased flexibility of Heat treated NiTi allows files to better follow the canal, but EdgeEndo® FireWire™ NiTi does away with shape memory and “Bounce Back” and therefore gives incredible canal contouring capability. Dentin is preserved and canals in apical third are preserved.
*Based on Internal Testing. Click here for testing methodology.
Dr. Andy Dosanjh – The University of Detroit Mercy
A pilot study conducted at the University of Detroit Mercy showed EdgeFile files to have significantly greater cycles compared to competing files. The purpose of this study was to examine the effect of different temperature changes on the cyclic fatigue of EdgeFile, Vortex Blue, and ESX rotary NiTi instruments. The three groups of NiTi rotary files were tested in a metal block that simulated a canal curvature of 60˚ and 5 mm radius of curvature. The block was submerged in a controlled-temperature water bath filled with water at four different temperatures. Thirty files from each experimental group were tested in the block at each of the four temperature cycles, and rotated at 500 rpm. Time to file fracture was recorded, and converted to number of cycles to fracture (NCF).
Vortex Blue files showed a significant decrease in NitTI cyclic fatigue as temperature increased from 3˚C to 60˚C. ESX files showed a significant decrease in NCF as temperature increased from 3˚C to 37˚C. EdgeFile files showed a significant increase in NitTI cyclic fatigue from 3˚C to 22˚C, and a significant decrease in NCF from 22˚C to 37˚C. For each temperature tested, EdgeFile files showed higher NCF than Vortex Blue files, and Vortex Blue files showed higher NitTI cyclic fatigue than ESX files. The findings showed that temperature does have an effect on the number of cycles to fracture for all rotary NiTi endodontic files tested. The findings from the study suggest that with the exception of files that are already in a martensitic phase, an irrigant chilled below room temperature seems favorable to increase NiTi cyclic fatigue.
In this in vitro study, temperature was found to have a significant effect on the cyclic fatigue of the NiTi rotary files tested. At each tested temperature, NCF of EdgeFile files were higher than NCF of Vortex Blue files, which was higher than NCF of ESX files. At all temperatures, EdgeFile files were found to have significantly higher cyclic fatigue than Vortex Blue files, which had significantly higher cyclic fatigue than ESX files. Since the cyclic fatigue of various file types was found to be significantly affected by temperature, future cyclic fatigue studies are recommended to be conducted at body temperature. Consideration should be taken in interpretation of studies conducted at room temperature.
Methods
Three groups of nickel-titanium rotary files (EdgeFile [EdgeEndo, Albuquerque, NM], Vortex Blue [Dentsply Tulsa Dental Specialties, Tulsa, OK], and ESX [Brasseler USA, Savannah, GA]) of size #25 with .04 taper and 25 mm length were tested in a metal block that simulated a canal curvature of 60˚ and 5 mm radius of curvature. The block was submerged in a controlled-temperature water bath filled with water at 3˚C ± 0.5˚C, 22˚C ± 0.5˚C, 37˚C ± 0.5˚C, and 60˚C ± 0.5˚C. Thirty files from each experimental group were tested in the block at each of the four temperature cycles, and rotated at 500 rpm. Time to file fracture was recorded, and converted to number of cycles to fracture (NCF). Statistical analysis was completed using a one-way ANOVA with post-hoc Tukey test.
Results
Vortex Blue files showed a significant decrease in NCF as temperature increased from 3˚C to 60˚C. ESX files showed a significant decrease in NCF as temperature increased from 3˚C to 37˚C. EdgeFile files showed a significant increase in NCF from 3˚C to 22˚C, and a significant decrease in NCF from 22˚C to 37˚C. For each temperature tested, EdgeFile files showed higher NCF than Vortex Blue files, and Vortex Blue files showed higher NCF than ESX files.
Conclusions
In this in vitro study, temperature was found to have a significant effect on the cyclic fatigue of the NiTi rotary files tested. At each tested temperature, NCF of EdgeFile files was higher than NCF of Vortex Blue files, which was higher than NCF of ESX files. Future cyclic fatigue studies should consider being conducted at body temperature.
One hundred twenty nickel-titanium rotary endodontic files were used for each of the three experimental file groups: EF (EdgeFile files; EdgeEndo, Albuquerque, NM), VB (Vortex Blue files; Dentsply Tulsa Dental Specialties, Tulsa, OK), and ESX (ESX files; Brasseler USA, Savannah, GA). All files were size #25 with .04 taper and 25 mm length, and were sterilized before use. The entire length of each file was placed into a simulated canal in a metal block, which was submerged in a water bath. The files were rotated at 500 rpm (which is within the recommended range of rotational speeds in the directions for use of each file system) with the use of an endodontic motor (Tulsa E3 motor). The metal block was made of tempered steel with a milled canal that simulated a 60˚ canal curvature and 5 mm radius of curvature, and a width of 1.5 mm. A digital thermometer was used to measure the temperature of the water before initiating testing of each file. Within each group of 120 files, files were randomly subdivided for testing at the four different temperature cycles, with 30 files per temperature cycle. The four different temperature cycles were ice water (3˚ ± 0.5˚C), room temperature (22˚ ± 0.5˚C), body temperature (37˚ ± 0.5˚C), and hot water (60˚C ± 0.5˚C). A picture of the setup is shown in Figure 1. A video record was made of each file rotation, and time to fracture was recorded in seconds. This was identified by visual and/or audible sound of fracture. Time to fracture was converted into NCF.
Figure 1. Water bath and electric motor setup
Results
A one-way ANOVA with post-hoc Tukey test was used to compare the cyclic fatigue of the instruments at different temperatures. The results are graphically shown in Figure 2. When the temperature cycle increased from 3˚C to 22˚C, the average NCF significantly (p<0.01) decreased for both VB and ESX, from 4842 (SD=1136) and 932 (SD=163) to 2062 (SD=358) and 466 (SD=66), respectively. However, the NCF significantly (p<0.05) increased for EF from 6185 (SD=2143) to 7243 (SD=2088). When the temperature cycle increased from 22˚C to 37˚C, all files showed a significant (p<0.01) decrease in the NCF, to averages of 1233 (SD=218), 271 (SD=55), and 1675 (SD=384) for VB, ESX, and EF, respectively. Further increasing the temperature from 37˚C to 60˚C caused a significant (p<0.01) reduction in the NCF for VB to an average of 651 (SD=111). ESX and EF also had reductions in their NCF to respective averages of 218 (SD=45) and 901 (SD=201), but these were not statistically significant. At each temperature, EF had a significantly (p<0.01) higher NCF than VB. VB had a significantly (p<0.01) higher NCF than ESX.
Discussion
Temperature has a significant effect
The findings of this study showed that temperature has a significant effect on the number of cycles to fracture for all rotary NiTi endodontic files tested. This is in agreement with previous studies (6, 7) where increasing the temperature was found to decrease the NCF. However, this study examined a greater variety of temperatures than the other studies.
This is of importance, because cyclic fatigue studies are usually conducted in an ex vivo setting where temperature is not considered as a variable. Future studies can be made more clinically relevant by being conducted at body temperature instead of room temperature. The NCF for the ESX and Vortex Blue files nearly halved when the temperature was increased from room temperature to body temperature, while that for EdgeFile files decreased by over four times. This large difference in NCF is apparent when compared to the other files.
For example, when compared to Vortex Blue files, at room temperature the NCF of EdgeFile files was over 3.5 times higher. When heated to body temperature, the NCF of EdgeFile files was only 1.35 times higher than Vortex Blue files; however, this was still significant. The metallurgic properties of endodontic files appear to affect their NCF in addition to temperature.
File types were selected to get a variation in metallurgy. The EdgeFile files are predominantly in a martensitic phase at room temperature, which is responsible for their lack of ‘shape memory.’ Further cooling of the EdgeFile files to 3˚C resulted in a decrease in the NCF. This decrease in NCF may be due to a mechanism similar to how traditional metals become more ‘brittle’ as they cool, causing them to fracture. Heating most likely caused a transition to an austenitic phase, reducing the NCF. Although there was a reduction in the NCF from 37˚C to 60˚C, this was not found to be statistically significant. Both the ESX and Vortex Blue files at least doubled their NCF when they were placed in ice water, since they may possess more austenitic phase at room temperature compared to EdgeFile files. By cooling them, they transitioned to a more martensitic phase. The difference in NCF for ESX files from 37˚C to 60˚C was not significant. This may be due to the files already being in mostly an austenitic phase at body temperature; consequently, further heating did not have an effect.
Using a heated NaOCl irrigant, however, has been shown to be effective for disinfection and tissue dissolution (2, 3). According to our findings, the use of a heated irrigant during file instrumentation may increase the incidence of file separation due to the reduction in NCF that may result. Furthermore, exposure of NiTi files to heated NaOCl may cause more corrosion leading to faster separation (9). Therefore, a heated NaOCl irrigant may be best suited as a final step in the irrigation protocol. In an in vivo study by de Hemptinne et al. (10), room temperature NaOCl solution injected into a canal increased temperature to 30.9˚C after only 10 seconds. The temperature of a heated solution decreased from 56.4˚C to 45.4˚C after 5 seconds and took a minute to decrease down to 37˚C. This rapid equilibration of temperature makes it especially important to test cyclic fatigue of instruments at body temperature instead of at room temperature, since irrigant at room temperature quickly equilibrates to body temperature when used in the root canal space. This experimental model used a metal block to simulate a root canal. The effects of conduction and insulation of heat are likely different in this model than those of root dentin, and may be a factor for in vivo results.
Notably, this study only examined cyclic fatigue; torsional fatigue and cutting effectiveness of files are also important aspects of a file’s performance. Future studies should examine the effects of temperature and file metallurgy on these characteristics.
Conclusion
In conclusion, when placed in a water bath, ESX files showed a decrease in NCF when heated from 3˚C up to 37˚C, but no significant difference was seen from 37˚C to 60˚C; Vortex Blue files showed the same, except they continued to have a reduction in NCF to 60˚C. EdgeFile files showed an increase in NCF from 3˚C to 22˚C, and a marked decrease in NCF from 22˚C to 37˚C. There was no statistically significant difference in NCF from 37˚C to 60˚C.
At all temperatures, EdgeFile files were found to have significantly higher NCF than Vortex Blue files, which had significantly higher NCF than ESX files.
Since the cyclic fatigue of various file types was found to be significantly affected by temperature, future cyclic fatigue studies are recommended to be conducted at body temperature. Consideration should be taken in interpretation of studies conducted at room temperature.
References
1. Montalveo D, Alçada FS, Fernandes FMB, et al. Structural Characterisation and Mechanical FE Analysis of Conventional and M-Wire Ni-Ti Alloys Used in Endodontic Rotary Instruments. Scientific World Journal 2014; Article ID 976459: 1-8.
2. Sirtes G, Waltimo T, Schaetzle M, et al. The Effects of Temperature on Sodium Hypochlorite Short-Term Stability, Pulp Dissolution Capacity, and Antimicrobial Efficacy. J Endod 2005; 31(9):669-671.
3. Dumitriu D, Dobre T. Effects of Temperature and Hypochlorite Concentration on the Rate of Collagen Dissolution. J Endod 2015; 41(6):903-906.
4. Shen Y, Zhou HM, Zheng YF, et al. Current Challenges and Concepts of the Thermomechanical Treatment of Nickel-Titanium Instruments. J Endod 2013; 39(2):163-172.
5. Merkel D, Brinkmann E, Wiens D, et al. In situ cooling with ice water for the easier removal of self-expanding nitinol stents. Endosc Int Open
2015;03:E51–E55.
6. Jamleh A, Yahata Y, Ebihara A, et al. Performance of NiTi endodontic instrument under different temperatures. Odontology 2015; 1-5.
7. de Vasconcelos RA, Murphy S, Carvalho CAT, et al. Evidence for Reduced Fatigue Resistance of Contemporary Rotary Instruments Exposed to Body Temperature. J Endod 2016; 42(5): 782-787.
8. Vera J, Ochoa-Rivera J, Vazquez-Carcaño, et al. Effect of Intracanal Cryotherapy on Reducing Root Surface Temperature. J Endod 2015; 41(11):1884-1887.
9. Peters OA, Roehlike JO, Baumann MA. Effect of Immersion in Sodium Hypochlorite on Torque and Fatigue Resistance of Nickel-Titanium Instruments. J Endod 2007; 33(5):589-593.
10. de Hemptinne F, Slaus G, Vandendael M, et al. In Vivo Intracanal Temperature Evolution during Endodontic Treatment after the Injection of Room Temperature or Preheated Sodium Hypochlorite. J Endod 2015; 41(7):1112-1115
X We use cookies to optimize our website and our service. This includes cookies that are necessary for the operation of our website and for our business interests, statistics, and marketing. You can agree to all cookies and data processing by clicking on the “Accept All” button or refuse consent by clicking on the “Reject All” button. You may visit Cookie settings to provide controlled consent or change your consent at any time. Further information can be found under our Privacy Policy and Cookie Policy. Accept AllReject AllCookie Settings Cookie PolicyPrivacy Policy
Manage consent
Privacy Overview
This website uses cookies to improve your experience while you navigate through the website. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may affect your browsing experience.
Necessary cookies are absolutely essential for the website to function properly. These cookies ensure basic functionalities and security features of the website, anonymously.
Cookie
Duration
Description
cookielawinfo-checkbox-advertisement
1 year
Set by the GDPR Cookie Consent plugin, this cookie is used to record the user consent for the cookies in the "Advertisement" category .
cookielawinfo-checkbox-analytics
11 months
This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Analytics".
cookielawinfo-checkbox-functional
11 months
The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional".
cookielawinfo-checkbox-necessary
11 months
This cookie is set by GDPR Cookie Consent plugin. The cookies is used to store the user consent for the cookies in the category "Necessary".
cookielawinfo-checkbox-others
11 months
This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other.
cookielawinfo-checkbox-performance
11 months
This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance".
PHPSESSID
session
This cookie is native to PHP applications. The cookie is used to store and identify a users' unique session ID for the purpose of managing user session on the website. The cookie is a session cookies and is deleted when all the browser windows are closed.
viewed_cookie_policy
11 months
The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data.
Functional cookies help to perform certain functionalities like sharing the content of the website on social media platforms, collect feedbacks, and other third-party features.
Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.
Cookie
Duration
Description
_gat
1 minute
This cookie is installed by Google Universal Analytics to restrain request rate and thus limit the collection of data on high traffic sites.
Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics the number of visitors, bounce rate, traffic source, etc.
Cookie
Duration
Description
_ga
2 years
The _ga cookie, installed by Google Analytics, calculates visitor, session and campaign data and also keeps track of site usage for the site's analytics report. The cookie stores information anonymously and assigns a randomly generated number to recognize unique visitors.
_gid
1 day
Installed by Google Analytics, _gid cookie stores information on how visitors use a website, while also creating an analytics report of the website's performance. Some of the data that are collected include the number of visitors, their source, and the pages they visit anonymously.
CONSENT
2 years
YouTube sets this cookie via embedded youtube-videos and registers anonymous statistical data.
Advertisement cookies are used to provide visitors with relevant ads and marketing campaigns. These cookies track visitors across websites and collect information to provide customized ads.
Cookie
Duration
Description
_fbp
3 months
This cookie is set by Facebook to display advertisements when either on Facebook or on a digital platform powered by Facebook advertising, after visiting the website.
fr
3 months
Facebook sets this cookie to show relevant advertisements to users by tracking user behaviour across the web, on sites that have Facebook pixel or Facebook social plugin.
IDE
1 year 24 days
Google DoubleClick IDE cookies are used to store information about how the user uses the website to present them with relevant ads and according to the user profile.
NID
6 months
NID cookie, set by Google, is used for advertising purposes; to limit the number of times the user sees an ad, to mute unwanted ads, and to measure the effectiveness of ads.
personalization_id
2 years
Twitter sets this cookie to integrate and share features for social media and also store information about how the user uses the website, for tracking and targeting.
test_cookie
15 minutes
The test_cookie is set by doubleclick.net and is used to determine if the user's browser supports cookies.
VISITOR_INFO1_LIVE
5 months 27 days
A cookie set by YouTube to measure bandwidth that determines whether the user gets the new or old player interface.
YSC
session
YSC cookie is set by Youtube and is used to track the views of embedded videos on Youtube pages.
yt-remote-connected-devices
never
YouTube sets this cookie to store the video preferences of the user using embedded YouTube video.
yt-remote-device-id
never
YouTube sets this cookie to store the video preferences of the user using embedded YouTube video.